Vape Sensor Plotting
The values calculated here are differences from the average of the first 2o samples. The X axis is time, but it’s not well-specified because I didn’t actually set a regular timer, I just collected samples as fast as possible.
As was predicted in the previous entry, the MQ-135 and MQ-3, both of which can sense alcohol, had the strongest response to vape clouds. These are the ones I’d use for the primary detection if I was building a serious vape detecting product.
The MQ-9 and MQ-8 had similar responses, but not as strong. This is kind of interesting, since they are supposed to be good for butane, propane, LPG, and hydrogen, but maybe they just do a decent job detecting light molecules with carbon in them? The MQ-2 response is interesting, since it’s sold as a LPG, propane, and hydrogen detector, but has a moderate response to vapes too.
The much lower results seems to indicate that vape clouds have no VOCs (CJMCU-1100) and no town gas or LPG (MQ-5, but I didn’t need a sensor to tell me that).
In Which Vapes May Yet Be Sensed
I’m coming to the “being a narc” thing a little late, since everyone is now having a panic about cutting agents in vapes killing people (Body count stands at ~15. The cops killed about 678 people so far this year, so y’know, keep vaping and avoid cops, it’s 45 times safer). At any rate, a school in my area was sold fantastically expensive devices that monitor areas for vaping, and report to the school administration when someone does it. The devices are on a subscription model, so they’re not just expensive once, they stay expensive.
This got me wondering what it actually takes to detect vape… vapor. Vape juice is mostly propylene glycol and glycerine, plus a dab of flavor and possibly nicotine. I have two theories about ways to detect this. One is that there will be some material produced by vaping that is detectable with a gas sensor. The other way is that phat clouds can be picked up by a particulate sensor, and the fact that it picks up smoke too is just fine, since the kids aren’t supposed to be smoking in the bathroom either.
MQ-2 | Combustable gasses, LPG, propane, hydrogen, probably also methane |
MQ-8 | Just hydrogen |
MQ-4 | Methane and natural gas |
MQ-3 | Alcohol |
MQ-6 | LPG, iso-butane, propane |
MQ-5 | LPG, natural gas, “town gas” |
MQ-135 | Carbon monoxide, carbon dioxide, ammonia, nitrogen oxide, alcohols, “aromatic compounds”, “sulfide”, and smoke |
MQ-9 | Carbon monoxide, LPG |
CMJU-1100 | VOCs, toluene, formaldehyde, benzene, and so on |
There’s a lot of overlap in these sensors, as well as a lot of ambiguity in their datasheets. “Sulfide” isn’t a thing without whatever it’s a sulfide of. Hydrogen sulfide is a toxic and terrible-smelling gas. Cadmium sulfide is a bright yellow solid. “Town gas” is typically a mix of carbon monoxide and hydrogen. LPG is also a mix, including propane, butane, and isobutane, so having it in a list with any of those is kind of redundant.
I haven’t tested yet, but I suspect that the sensors most likely to detect sick clouds are the MQ-3, the MQ-135, and maaaaybe the CMJU-1100. The MQ-3 claims to detect alcohol, as in a breathalyzer, but the family of alcohols is actually pretty large. There’s ethyl (drinkin’ alcohol) and isopropyl (cleanin’ alcohol) and methyl (killin’ alcohol), in addition to some stuff people don’t typically think of as alcohols, like the sugar alcohols, which includes glycerine. Since glycerine is in vape juice, perhaps the sensor will detect it.
The actual mechanism of these sensors is interesting. They appear to the circuit as a resistor that changes resistance in the presence of a gas. The resistor is made of tin dioxide, which has a resistance that drops when exposed to the gasses, but it only responds quickly if the device is hot, so there is also a built-in heater for the sensors.
Because the sensors have little heaters in them, A) they smell weird when they power up for the first time and B) they take a while to stabilize. I powered them up and watched them on the Arduino serial plotter until the outputs more or less leveled out. Then I vaped at them.
Pretty much all of the sensors had some sort of response, but the thing that seemed to vary between them was that some responded faster than others. The next step is going to be logging which ones are outputting what, so I can tell which ones had the fast response and which ones had the strongest response.
The sensors also have a slight response when I just blow at them with normal breath (I have a control! I’m a scientist, doin’ a science!). Interestingly, for some of the sensors, the reaction to my normal breath was a deviation downwards/towards a lower value, while the vape reactions was uniformly a deviation upwards/towards a higher value. This suggests that including one of the sensors that indicates vaping by the sign of its change would serve as a check, since only vaping would cause both sensors to go up, and normal breath would cause one to go up and one to go down.
int readings[9] = {0,0,0,0,0,0,0,0,0}; int index = 0; void setup() { Serial.begin(9600); } void loop() { //Read all the analog inputs from A0-A8 (I think they're consecutive...) index = 0; for(int ii = A0; ii <= A8; ii++ ){ readings[index] = analogRead(ii); index++; } for(int jj = 0; jj < index-1; jj++){ Serial.print(readings[jj]); Serial.print(","); } Serial.println(readings[index-1]); }
On Looking into Mouse Sensors
That is to say, the sensors from optical mice, rather than a sensor intended to detect the small rodent.
I have 10 boards from optical mice and three desoldered sensors. Among that bunch there are two common IC packages, a 16-pin staggered DIP (4 units) and an 8-pin staggered DIP (6 units). There is also a 20-pin staggered DIP, and two 12-pin DIP packages.
Most of the chips were made by Agilent, or Avago, a spin-off of Agilent that eventually bought Broadcom and started operating under that name. A couple are from At Lab, or as they style themselves “@lab”.
The chip interfaces are very heterogeneous. Some of them just output PS2 data and clock signals, and so are a very integrated mouse IC. Some of them output quadrature signals for x and y motion.
I had high hopes for using these mouse sensors for a couple of hacks. One of them is that they are essentially optical flow processors, so you can use them to either get velocity based on the observed motion of stationary objects from a moving platform, assuming you know how far away the objects are (and so get odometry for a moving robot by watching the ground roll by). The inverse of that is that you can also get how far away an object is assuming that it is stationary and you know your own speed (for height over ground detection in a drone, for example).
Ultimately, though, I don’t think this stash of ICs is going to do the job I want. What I want is something I can drop into projects I’m working on, and reverse engineering each of these, finding the datasheets for ICs old enough to support PS2 protocol, and so forth, would be its own hassle of a project. USB optical mice are $7 or so, so I can’t really justify the effort to get these working, sort out optics for them, etc.
On top of that, drone optical flow sensors with the optics already sorted are like $10-20, so for that use case, I can just buy the part. For robot odometry, I can use the same part, or put optics on a USB mouse that can actually plug into a recent computer, instead of decoding quadrature or PS2.
It feels kind of weird to pick up one of my old projects that I had been kind of looking forward to, and realize that it’s simply not useful or interesting, but I guess that’s just how it goes. At least I can free up that parts drawer now!